E-ISSN: 2321-6646 | Contact
Microleakage and Environmental pH Influence in Primary Molars Restored with Self-Curing Bulk-Fill Composite, Light-Curing Bulk-Fill Composite, and Conventional Composite: An In Vitro Comparative Evaluation
1Master Program in Pediatric Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
2Department of Pediatric Dentistry, Saint Joseph University of Beirut, Faculty of Dentistry, Beirut, Lebanon
Journal of Pediatric Dentistry 2026; 12(1): 8-16 DOI: 10.14744/JPD.2026.5_364
Full Text PDF

Abstract

Objective: The objective of this study was to compare microleakage and the influence on environmental pH of conventional composite (Neo Spectra® ST Universal Dentsply, Sirona, USA), light cured bulk-fill (SDR® Dentsply, Sirona, USA), or self-polymerizing bulk-fill (STELA®, SDI, Australia).
Materials and Methods: Forty-five extracted primary molars were randomly allocated into three groups (n=15) and restored with Neo Spectra® ST Universal, SDR®, or STELA® using an etch-and-rinse protocol. Microleakage was assessed after thermocycling by dye penetration (1% methylene blue), sectioning, and evaluation under a stereomicroscope using a standardized scoring system. For pH analysis, sixty-nine standardized cylindrical specimens of each material (n=23) were immersed in saline, and pH changes were measured at multiple time intervals using a calibrated electrode to evaluate their influence on the surrounding environment.
Results: Fisher’s Exact test was performed to evaluate the microleakage score within the three restorative materials. A statistically significant association was found between restorative material and microleakage score (p=0.004), with Neo Spectra® ST Universal showing higher microleakage, while SDR® and STELA® demonstrated improved marginal adaptation. A mixed repeated measures of ANOVA was run to assess the effect of the three types of composite on the environmental pH. pH values changed significantly over time (p<0.0001), with conventional composite Neo Spectra® ST Universal exhibiting the highest pH, SDR® intermediate values, and STELA® the lowest. Significant differences were observed between all groups (p<0.0001).
Conclusion: Bulk-fill and bioactive restorative materials, particularly bulk-fill SDR® and self-polymerizing bulk-fill STELA®, showed superior sealing ability compared to conventional composite Neo Spectra® ST Universal. Additionally, STELA® demonstrated dynamic pH modulation, suggesting potential antibacterial and remineralization benefits, making it a promising material for pediatric restorative dentistry.